Performance
Precision coverage
● Reference was made to multiple databases (COSMIC & TCGA) and guidelines to select regions more likely to contain mutations.
●~90% of cases have at least one mutation, and ~60% of cases have three or more mutations (AML_OHSU_2022 cohort).
● Covers approximately 42.5 Kb of the genome, allowing detection of base substitutions, insertions/deletions, and gene fusions in 32 genes associated with AML.
Gene list
Note:* Indicates that the gene is covered across the entire coding sequence (CDS) region; † Indicates that the gene is covered in fusion-related intronic regions.
ASXL1
Exon 12,13
BRINP3
Exon 3,8
CBL
Exon 8,9
CEBPA*
Full CDS
DNMT3A
Exon 8-23
EZH2
Exon 4-6,8,13-20
FLT3
Exon 14,15,20
GATA2
Exon 3-6
HNRNPK
Exon 4-6,10,12,15,16
IDH1
Exon 4
IDH2
Exon 4
JAK2
Exon 14
KIT
Exon 8,17
KMT2A†
Intron 8-10
KRAS
Exon 2,3
MYH11†
Intron 32
NPM1
Exon 10,11
NRAS
Exon 2,3
PHF6*
Full CDS
PTEN
Exon 5,7
PTPN11
Exon 3,13
RAD21*
Full CDS
RUNX1*
Full CDS
SF3B1
Exon 14,15
SMC1A
EXON 2,9,11,13,15-17,22
SMC3
Exon 9,10,13,19,24,25,27
SRSF2
Exon 1
STAG2
Exon 4,5,7-9,14,16,18,19,24,26-30
TET2*
Full CDS
TP53*
Full CDS
U2AF1
Exon 2
WT1
Exon 6-9
Low background noise
Higher sensitivity
Figure 2. Duplex depth (DCS211) detected by μCaler AML MRD comprehensive solution and sonication-based library preparation under different input conditions. The μCaler AML MRD comprehensive solution user manual was used as a reference, and the filtering was performed based on Duplex Consensus Sequences (DCS211). The sequencing mode is Illumina Novaseq 6000, PE150.
Lower sequencing cost
Figure 3. Minimum amount of raw data required for μCaler AML MRD comprehensive solution and traditional hybridization capture method to achieve a specific depth (satisfying Duplex Consensus Sequences analysis).
Note:Traditional indicates the conventional hybridization capture method, calculated based on the on-target rate of 15%.
Stable and efficient
Figure 4. Stability performance of μCaler AML MRD comprehensive solution in different experimental batches. A.On-target rate; B. Uniformity of data yield. The captured library were prepared from gDNA samples according to the user manual of μCaler AML MRD comprehensive solution. Using BWA to alignment to the reference genome hg19 and on-target rate was calculated by the number of reads.
High-speed and convenient
Capture performance
Figure 5. Capture performance of μCaler AML MRD comprehensive solution. 300 ng of fragmented DNA were used to prepare the pre-library, and the hybridizationcapture was completed with μCaler AML Panel v1.0. A. Mappability, Ontargetand target covered; B. Sequencing depth; C. Coverage uniformity and consistency.
Note:The samples were derived from the proportionate mixing of Pancancer Light 800 gDNA Reference Standard (Genewell, GW-OGTM800) and Human Male Genomic DNA Standard (Promega, G1471) to simulate samples with different allele frequency (0.025%~0.1%).
Analysis of mutation in standard
Figure 6. Mutation analysis of the μCaler AML MRD comprehensive solution. A. Average depth (DCS211 ≥ 1); B. Reads supporting mutations; C. Theoretical and observed mutation frequencies.
Note:The sequencing mode is Illumina Novaseq 6000, PE150.
NEM Fragment Module
Color of Tube Cap | Component |
Volume 1002801(24 rxn) |
|
NEM Fragment Buffer | 60 μL |
|
NEM Fragment Enzyme Mix | 60 μL |
|
Stop Solution | 150 μL |
/
/
Packing No.
Color of Tube Cap
Component
Volume
1002101 (24 rxn)
Volume
1002103 (96 rxn)
Box1
EndRepair & A-Tailing Buffer
180 µL
690 µL
End Repair & A-Tailing Enzyme
120 µL
460 µL
Ligation Buffer
750 µL
2×1500 µL
DNA Ligase
65 µL
250 µL
2X HiFi PCR Master Mix
720 µL
2×1600 µL
NadPrep Amplification Primer Mix II
145 µL
650 µL
Nuclease Free Water
2.5 mL
8 mL
TE Solution
1 mL
4 mL
Box2
NadPrep SP Beads
4 mL
15 mL
/
/
Adapter Module
Packing No.
Color of Tube Cap
Component
Volume
1002211(24 rxn)
Volume
1002212 (96 rxn)
Box1
EndRepair & A-Tailing Buffer
180 µL
690 µL
End Repair & A-Tailing Enzyme
120 µL
460µL
Ligation Buffer
750 µL
2×1500 µL
DNA Ligase
65 µL
250 µL
2X HiFi PCR Master Mix
720 µL
2×1600 µL
NadPrep M-Amplification Primer Mix (for MGI, SI)
20 µL
75 µL
NadPrep M-Amplification Primer Mix (for MGI, DI)
20 µL
75 µL
Nuclease Free Water
2.5 mL
8 mL
TE Solution
1 mL
4 mL
Box2
NadPrep SP Beads
4 mL
15 mL
Color of Tube Cap |
Component |
Volume 1103111 (24 rxn) |
Volume 1103121 (96 rxn) |
Volume 1103122 (96 rxn) |
|
NadPrep Universal UDI-Index Primer Mix # | 12×15 µL | 24×25 µL | 24×25 µL |
|
NadPrep UMI Adapter | 60 µL | 230 µL | 230 µL |
|
NadPrep Amplification Primer Mix II | 20 μL | 75 μL | 75 μL |
Blocker
Color of Tube Cap
Component
Volume
1003911 (24 rxn)
Volume
1003921 (96 rxn)
Volume
1003922(96 rxn)
Volume
1003925 (96 rxn)
Volume
1003926 (96 rxn)
NadPrep M-Index (MDI) Primer Mix #
12×15 µL
24×25 µL
24×25 µL
24×25 µL
24×25 µL
NadPrep BMI-Adapter
60 µL
230 µL
230 µL
230 µL
230 µL
Color of Tube Cap |
Component |
Volume 1106102 (16 rxn) |
Volume 1106101 (96 rxn) |
|
μCaler NanoBlockers (for Illumina) | 40 μL | 210 μL |
Blocker
Color of Tube Cap |
Component |
Volume 1106212 (16 rxn) |
Volume 1106211 (96 rxn) |
|
μCaler NanoBlockers (for MGI, DI) | 40 μL | 210 μL |
Hybrid Capture
Packing No. |
Color of Tube Cap |
Component |
Volume 1105102 (16 rxn) |
Volume 1105101 (96 rxn) |
Box 1 |
|
μHyb #1 | 840 μL | 3×1700 μL |
|
μHyb #2 | 130 μL | 790 μL | |
|
Human Cot DNA | 45 μL | 260 μL | |
Box 2 |
|
Streptavidin Beads | 480 μL | 2.9 mL |
/ |
Wash Buffer A | 2×5.3 mL | 3×21 mL | |
/ |
Wash Buffer B | 2.9 mL | 20 mL |
Panel
Catalog |
Color of Tube Cap |
Component |
Volume |
1101412 |
|
μCaler AML Panel v1.0, 16 rxn | 40 μL |
1101411 |
|
μCaler AML Panel v1.0, 96 rxn | 210 μL |
Type | Product | Detail | Catalog# |
NEM Fragment Module | NadPrep NEM Fragment Module, 24 rxn | 24 rxn | 1002801 |
Lib Prep Module | NadPrep DNA Library Preparation Kit (for Illumina®) G24 | 24 rxn | 1002101 |
NadPrep DNA Library Preparation Kit (for Illumina®) E96 | 96 rxn | 1002103 | |
Adapter Module | NadPrep UMI Adapter Kit Set A1 (with 10 nt Index), 24 rxn | 1-12 | 1103111 |
NadPrep UMI Adapter Kit Set B1 (with 10 nt Index), 96 rxn | 1-24 | 1103121 | |
NadPrep UMI Adapter Kit Set B2 (with 10 nt Index), 96 rxn | 25-48 | 1103122 | |
NadPrep BMI Adapter (MDI) Module Set A1 (for MGI), 24 rxn | MDI 1-12 | 1003911 | |
NadPrep BMI Adapter (MDI) Module Set B1 (for MGI), 96 rxn | MDI 1-24 | 1003921 | |
NadPrep BMI Adapter (MDI) Module Set B2 (for MGI), 96 rxn | MDI 25-48 | 1003922 | |
NadPrep BMI Adapter (MDI) Module Set B3 (for MGI), 96 rxn | MDI 49-72 | 1003925 | |
NadPrep BMI Adapter (MDI) Module Set B4 (for MGI), 96 rxn | MDI 73-96 | 1003926 | |
Blocker | μCaler NanoBlockers (for Illumina®), 16 rxn | 16 rxn | 1106102 |
μCaler NanoBlockers (for Illumina®), 96 rxn | 96 rxn | 1106101 | |
μCaler NanoBlockers (for MGI, DI), 16 rxn | 16 rxn | 1106212 | |
μCaler NanoBlockers (for MGI, DI), 96 rxn | 96 rxn | 1106211 | |
Hybrid Capture | μCaler Hybrid Capture Reagents, 16 rxn | 16 rxn | 1105102 |
μCaler Hybrid Capture Reagents, 96 rxn | 96 rxn | 1105101 | |
Panel | μCaler AML Panel v1.0, 16 rxn | 16 rxn | 1101412 |
μCaler AML Panel v1.0, 96 rxn | 96 rxn | 1101411 |
Nanodigmbio will contact you within 1 day.
If there are any problems, please contact us by 400 8717 699 / support@njnad.com